BWMYS - ACID NICKEL BRUSH PLATE

  • MSDS: BWMYS
  • Manufacturer: TECHNIC INC
  • Product Name: ACID NICKEL BRUSH PLATE
  • National Stock Number: 6850-00N056130
Product Identification

Product ID:ACID NICKEL BRUSH PLATE
MSDS Date:03/29/1993
FSC:6850
NIIN:00N056130
MSDS Number: BWMYS

Responsible Party
TECHNIC INC
1 SPECTACLE ST
CRANSTON, RI 02910
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 401-781-6100

Preparer: WILLIAM A WILSON

Cage: 20816

Contractor
TECHNIC INC
CRANSTON, RI 02910 US

Telephone: 401-781-6100

Cage: 20816

Ingredients

NICKEL SULFATE (SARA 313) (CERCLA)

CAS: 7786-81-4

RTECS: QR9350000

Fraction By Weight: 40.30%

OSHA PEL 1 MG(NI)/M3

ACGIH TLV: 0.1 MG(NI)/M3

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


NICKEL CHLORIDE (SARA 313) (CERCLA)

CAS: 7718-54-9

RTECS: QR6475000

Fraction By Weight: 1.56%

OSHA PEL 1 MG(NI)/M3

ACGIH TLV: 0.1 MG(NI)/M3

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:LOCAL:IRRITANT, ALLERGEN,
INGESTION, INHALATION - SLIGHT. CAUSES READILY REVERSIBLE CHANGES
WHICH DISAPPEAR AFTER END OF EXPOSURE. SYSTEMIC:INGESTION,
INHALATION - SLIGHT. CAUSES READILY REVERSI BLE CHANGES WHICH
DISAPPEAR AFTER END OF EXPOSURE. CHRONIC:LOCAL:IRRITANT, ALLERGEN -
SLIGHT TO (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:MODERATE. MAY INVOLVE BOTH
IRREVERSIBLE & REVERSIBLE CHANGES; NOT SEVERE ENOUGH TO CAUSE
DEATH/PERMANENT INJURY. SYSTEMIC:INHALATION - MODERATE. MAY INVOLVE
BOTH IRREVERSIBLE AND REVERSIBLE C HANGES; NOT SEVERE ENOUGH TO
CAUSE DEATH OR PERMANENT INJURY. SIGNS & SYMP OF
OVEREXP:INHAL:UPPER RESP TRACT (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYE:FLUSH W/WATER (15 MINS/LONGER). CALL PHYS. SKIN:WASH
THORO W/SOAP & WATER. CALL PHYS. INHAL:REMOVE TO FRESH AIR. IF
BRTHG DIFFICULTIES DEVELOP, CALL PHYS. INGEST:INDUCE VOMIT IF
CONSCIOUS. MAINTAI N RESPIRATION. CALL PHYS.

Fire Fighting

Extinguishing Media:WATER SPRAY.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:FLUSH W/WATER AFTER ABSORBING ON CLAY OR
SAWDUST. DISPOSE OF AT PROPER WASTE DISPOSAL OR SITE, OR RECOVER
NICKEL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP CONTAINER CLOSED. STORE IN COOL,
DRY PLACE. (55-85 F).
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NOT REQUIRED NORMALLY. NIOSH/MSHA APPROVED
RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST.
Protective Gloves:RUBBER GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKER GOGGLES .
Other Protective Equipment:RUBBER APRON, LONG-SLEEVED SHIRTS.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
EFTS OF OVEREXP:IRRIT. HYPERSENSITIVE INDIVIDUALS MAY DEVELOP ASTHMA
BRONCHITIS. SKIN/EYES:IRRITATION, ALLERGIC SENSITIZATION IN SOME
INDIVIDUALS IN PRESENCE OF HEAT & HUMIDITY. (NICKEL ITCH). INGEST:
NAUSEA, GASTROINTESTINAL PROBLEMS, UNCONSCIOUSNESS.

Chemical Properties

Solubility in Water:VERY SOLUBLE
Appearance and Odor:GREEN SOLUTION; ACID ODOR

Stability

Stability Indicator/Materials to Avoid:YES
CYANIDES.
Stability Condition to Avoid:DO NOT MIX WITH CYANIDES.
Hazardous Decomposition Products:NONE.

Disposal

Waste Disposal Methods:SHOULD BE IN ACCORDANCE WITH FEDERAL, STATE, AND
LOCAL ENVIRONMENTAL CONTROL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.